Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Company News
Home ProductsFire Tube Steam Boiler

Safe Operate Fire Tube Steam Boiler Automatic Control System SGS Certification

Good quality Oil Steam Boiler for sales
Good quality Oil Steam Boiler for sales
Yuanda boiler service is so good, especially the sales lady Kara,when i ask for something details about boiler,she always explain and reply on-line.

—— Kahramon

Yuanda Boiler Corporation with nice service and high quality and high reputation. One of our reliable supplier , goods are delivered in time and nice

—— Martin

Thanks for your good after-sale service. Excellent training and technology support help a lot.

—— Juan

I'm Online Chat Now

Safe Operate Fire Tube Steam Boiler Automatic Control System SGS Certification

China Safe Operate Fire Tube Steam Boiler Automatic Control System SGS Certification supplier

Large Image :  Safe Operate Fire Tube Steam Boiler Automatic Control System SGS Certification

Product Details:

Place of Origin: Henan,China
Brand Name: Yuanda
Certification: ISO9001,SGS
Model Number: WNS

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: Negotiable
Packaging Details: Cooperated with professional transportation team for the handing the land loading transport
Delivery Time: about 15-25 working days after payment
Payment Terms: L/C, D/A, T/T, D/P, Western Union
Supply Ability: 200 sets per month
Contact Now
Detailed Product Description
Product Name: Safe Operate Fire Tube Steam Boiler Automatic Control System Steam Boiler Capacity: 1ton To 20ton
Fuel: Light Oil,heavy Oil,natural Gas Steam Temperature: 194°C - 226°C
Thermal Efficiency: 92 % Operation: Automatic & Safety
Working Pressure: 0.7MPa, 1.0MPa, 1.5MPa Quality Control: Strict Quality System

Safe Operate Fire Tube Steam Boiler Automatic Control System Steam Boiler

 

Boiler description

 

WNS series gas/oil fired steam boiler is horizontal three pass fire tube wet back full automatic steam boiler. It normally suitable for 500kg to 20ton/h capacity, use all kinds of gas and oil fuels,such as natural gas, lpg,lng,cng,city gas,biogas, diesel oil,heavy oil.

1. Model:WNS

2. Capacity:500kg/h-20ton/h

3. Design pressure:1.0Mpa(10bar), 1.25Mpa(13bar), 1.6Mpa(16bar),2.5Mpa(25bar)

4. Stem temperature:below 224 degree

5. Design fuel:natural gas, lpg,lng,cng,city gas,biogas, diesel oil,heavy oil

6. Structure: three pass fire tube wet back

 

Technical parameter

 

Boiler model Capacity Pressure Feed temp. Steam temp. Fuel consump. Thermal efficiency
Natural gas Liquid gas
t/h Mpa m3/h m3/h %
WNS1-1.0-Y(Q) 1 1 20 184 84.2 29 91
WNS 2-1.25- Y(Q) 2 1.25 20 194 165 57.3 92
WNS3-1.25-Y(Q) 3 1.25 20 194 250 82 92.1
WNS4-1.25- Y(Q) 4 1.25 20 194 323.6 109 93
WNS5-1.25- Y(Q) 5 1.25 20 194 386 140 93
WNS6-1.25- Y(Q) 6 1.25 20 194 450 164 93.2
WNS8-1.25- Y(Q) 8 1.25 105 194 642 209 93.5
WNS10-1.25- Y(Q) 10 1.25 105 194 805 264 93.5
WNS15-1.25- Y(Q) 15 1.25 105 194 1182 400 93.5
WNS20-1.25- Y(Q) 20 1.25 105 194 1597 520 93.5

 

Boiler Advantages of fire tube steam boiler

 

1. WNS series oil Gas fired steam boiler realize high efficient heat transfer, sufficient burning with brand burner, environment protection
2. Adopted international latest technology for big volume combustion room design, and use brand burner machine
3. Corrugated furnace design make large heat transfer area and protect furnace
4. Using spirally corrugated tube , 1-2 faster heat transfer efficiency and remove hidden danger of welding cracks
5. Adopted wet-back structure that can reduce faults rate and maintenance cost
6. Equipped with protection devices for overheating, overpressure, lacking water, leak detection, flameout etc

 

How to choose gas oil fired steam boiler?


Nowadays,gas steam boiler is widely used, generally used for chemical, pharmaceutical and other industries.Functions of steam mainly are Curing, drying, sterilizing, disinfecting lamp.

 

1. Determine evaporation;
Selection of the boiler hourly steam production must be greater than the production needs of the steam, the production, the boiler can be 70% -100% load state operation, are the best running state;

 

2. Determine using pressure;
Boiler use pressure determined by the production process, selection, the boiler design pressure must be greater than the actual operating pressure to ensure that the boiler below the design pressure in the state of operation to ensure the safety of the boiler to ensure the operating results;

 

3. Determine the auxiliary equipment;
After confirm boiler evaporation and using pressure, you need to select the auxiliary equipment, what accessories equipment you choose, directly determine the running effect of boiler effect, also determine the price of boiler equipment;

 

Safe Operate Fire Tube Steam Boiler Automatic Control System SGS Certification

Contact Details
Henan Yuanda Boiler Co., Ltd.

Contact Person: Luna

Tel: 86-18236951735

Send your inquiry directly to us (0 / 3000)